Basements are rare here, so most Central Texas homes will never need a sump pump. The ones that do need it badly. A garage cut into a Hill Country slope, a walk-out lower level, a crawl space that collects runoff, a sunken courtyard or window well, an elevator pit, or a bathroom plumbed below the level of the sewer line: in each case, water or waste has to be lifted to get out, and gravity is not going to do it. When the region gets one of its flash-flood downpours, that pump is the only thing between the rain and your floor.
Radiant’s licensed plumbers assess whether you actually need a pump, and we will say so if you do not. Where you do, we size it for the volume of water it has to move and the height it has to lift, set the pit and check valve so it does not short-cycle, route the discharge away from the foundation, and add a battery backup when losing the pump during a storm-related outage would mean losing the room. For below-grade bathrooms and laundry rooms we install sewage ejector pumps, which are a different animal from a sump pump and are sealed and vented accordingly.
Every install and repair is priced in writing before we begin, and it is covered by the Home Comfort Guarantee. If you are not sure what you have in that pit in the garage, we will come look.
What to Watch For
A pump that fails does it silently, usually in the middle of the storm you bought it for. These are the warnings.
A stuck float, a failed check valve letting water fall back into the pit, or a pump too small for the inflow. All of them wear the motor out fast.
Debris in the impeller or a bearing on its way out. A hum with no pumping means the impeller is jammed or the motor has seized.
The float is not triggering, the pump has failed or the discharge line is blocked or frozen. Test it now, not during the next storm.
The pump is running but not keeping up, or water is finding a path around the pit. Either way, the room is losing.
A motor drawing too much current, a water-damaged cord or a short. Do not keep resetting it; that is a pump telling you it is done.
Pumps sit idle for months here, and idle pumps seize. A quick bucket test tells you whether it will run when it counts.
What We Handle
Assessment, installation, repair and the maintenance that keeps a pump ready for the storm.
How It Works
Honest assessment first. Not every wet garage needs a pump, and we will tell you which kind yours is.
Where the water shows up, when, and whether there is already a pump. We book a visit, or dispatch now if it is flooding.
Inflow, lift height, discharge route and power. On an existing pump, a full function test of float, check valve and motor.
Repair, new pump, ejector system or backup, each priced. The quote is honored for 72 hours.
The pit is filled, the pump cycles, the backup is tripped, and the discharge is watched at the outlet before we leave.
Save on the work your home needs most.
A licensed plumber can test it, fix it or replace it before the rain, with a written price first.
Don't just take our word for it — hear from our satisfied customers
Maintenance Membership
Home maintenance for $9.99 a month.
Care Club members get two HVAC tune-ups and a plumbing safety inspection every year, priority scheduling, no dispatch fees — ever — and 5% off every repair.
Most do not. Central Texas homes are overwhelmingly built on slabs with no basement, and rainwater is handled by grading and surface drainage. A sump pump becomes necessary when part of the home sits below the surrounding grade or below the sewer line: a garage or lower level cut into a Hill Country hillside, a crawl space that takes runoff, a sunken patio or window well, an elevator pit, or a bathroom in a below-grade addition. Our region also gets intense, fast rain events, so when a low spot does exist, it can fill quickly. If you are not sure, we would rather come look at how water moves around your home than sell you a pump you do not need.
Pour water into the pit, enough to raise the float. The pump should start, the water should drop quickly, and the pump should shut off on its own. Then watch for a minute: if water rises back into the pit right away with no new inflow, the check valve is letting the discharge line drain backward. Listen for grinding or a hum without pumping, and check that the discharge outlet outside is actually releasing water. Do this a couple of times a year, and always before a forecast of heavy rain. If the pump does not start, do not assume the outlet is dead and plug something else in to check; call us, because a pump that has seized can trip a breaker or worse.
If losing the pump would mean losing the room, yes. Sump pumps are needed most during severe weather, and severe weather is when the power goes out. A battery backup is a second pump in the same pit, on its own float, powered by a battery that charges from the wall. When the primary pump loses power or fails outright, the backup takes over for hours. It is also insurance against the more common failure, a primary pump that simply dies with the power on. For a finished lower level, a garage full of stored belongings or a below-grade bathroom, the backup usually costs far less than one flood would. For a pit that rarely sees water, we will tell you it is optional.
A sump pump moves clean groundwater and rainwater out of a pit and discharges it outside, away from the foundation. A sewage ejector pump moves wastewater, including solids, from fixtures that sit below the level of the main sewer line, and pumps it up into the sewer. That means a bathroom, laundry room or kitchen in a lower level or a below-grade addition. Ejector systems use a sealed, vented basin and a pump built to pass solids, and they are installed and permitted differently from a sump. Using a sump pump for sewage, or the other way around, ends badly. When you call about a pump in the floor, we will identify which one you have and service it accordingly.
The usual answer is a failed check valve. Each time the pump shuts off, the water still in the discharge pipe falls back into the pit, the float rises, and the pump starts again. A new check valve fixes it. Other causes are a float switch set too low or hung up on the pit wall, a pit that is too small for the inflow, or a genuine steady source of water such as a high water table after a wet spell, a leaking supply line nearby or irrigation runoff draining toward the pit. Short cycling wears out a pump quickly, so it is worth a visit. If the pit is filling from a leak rather than groundwater, we can trace that too.