Backflow Preventers
Your plumbing is designed so water moves from the utility main into the house and out through fixtures. But pressure in the main is not constant. A fire hydrant opens down the street, a main breaks, a pump kicks on, and for a moment the pressure in the street drops below the pressure in your yard. When that happens, water can be pulled backward, and what comes with it is whatever it was touching: fertilizer and pesticide from the sprinkler heads, pool chemicals, a hose left in a bucket of soap, or water from a boiler. A backflow preventer is a set of check valves and vents that closes that door automatically, protecting your family’s water and the neighborhood’s.
That is why most water utilities in Texas require a backflow prevention assembly on an irrigation system, and many require periodic testing by a licensed tester with a report on file. Radiant installs the correct type of assembly for the hazard, tests it with a calibrated gauge, repairs the checks and relief valves when they foul, and replaces assemblies that a hard freeze like February 2021 split open. For the specific device most sprinkler systems use, see our pressure vacuum breaker page. We also protect assemblies against winter on our frozen pipe visits, and check them as part of a whole-home plumbing inspection. New service lines to pools, outdoor kitchens and detached buildings get backflow protection sized in from the start; see water line services.
What to Watch For
Most of these show up at the assembly itself, usually near the meter or where the irrigation line branches off.
Utilities track assemblies and send reminders when a test is due. Ignoring it can lead to fines or a shutoff of the irrigation service.
A relief valve or air inlet discharging on and off is often normal; a steady stream means a fouled check that needs a rebuild.
Assemblies sit above ground full of water. A hard freeze splits the brass body or bonnet, and the leak appears when the system runs in spring.
A check valve stuck partly closed or debris caught in the seat robs the irrigation system of flow.
Any new connection that can hold contaminated water needs the right protection installed and, usually, an initial test.
If the ball valves on either side will not turn, the assembly cannot be isolated for testing or repair, and needs work first.
What We Do
Install, test, rebuild, replace and protect, for every assembly type found on Central Texas homes.
How It Works
A test does not take long. A repair, if it needs one, can often be done on the same visit.
We find the assembly, confirm the type and serial, and close the downstream shutoff so the irrigation system is briefly off.
A calibrated gauge on the test cocks measures each check valve and, on a reduced pressure assembly, the relief valve, against the required values.
If it passes, the report is completed. If not, you get a written price for a rebuild or replacement and we can do it right then.
Any repaired assembly is retested to confirm it passes, the results recorded, and the irrigation system turned back on.
Save on the work your home needs most.
We test, repair if needed, and complete the report. One visit, priced upfront.
Don't just take our word for it — hear from our satisfied customers
Maintenance Membership
Home maintenance for $9.99 a month.
Care Club members get two HVAC tune-ups and a plumbing safety inspection every year, priority scheduling, no dispatch fees — ever — and 5% off every repair.
Backflow is water moving the wrong way through your plumbing, from your property back toward the public main. It happens two ways. Backsiphonage is when pressure in the main drops suddenly, from a broken main or a hydrant being opened, and water gets pulled backward out of your pipes. Backpressure is when something on your side, like a pump or a boiler, pushes at higher pressure than the main. Either way, water that has been sitting in sprinkler lines with fertilizer, in a pool, or in a hose in a bucket can end up in the drinking water, not just yours but your neighbors’. That is why utilities require assemblies on connections with a contamination risk and track that they are tested and working.
Almost certainly, yes. Irrigation is the most common backflow hazard on a residential lot, because sprinkler heads sit in soil that has been fertilized and treated, and a pressure drop in the main can pull that water back through the heads and into the supply. Most water utilities in Texas require an approved backflow prevention assembly on any irrigation connection, and most require it to be tested when installed and periodically after that by a licensed tester. If your system was installed by a licensed irrigator, it should already have one, usually a pressure vacuum breaker near the meter. If you are not sure your system has one, or that it has been tested, we can check it on a service visit and get you current.
Your water utility sets the schedule, and annual testing is the most common requirement for residential irrigation assemblies. Some utilities require a test only at installation for lower-hazard connections and yearly for higher-hazard ones, and the rules differ between Austin, San Antonio and the smaller cities and water supply corporations around them. The utility typically sends a notice when a test is due, with a deadline and the form they want submitted. Whatever your utility requires, we test to it, record the results and give you what you need to file. Testing also catches problems early: a check valve that is starting to foul is a cheap rebuild now and a replacement later.
It depends on where the water is coming from and whether it stops. A reduced pressure assembly has a relief valve underneath that is designed to discharge briefly when supply pressure fluctuates; a spurt now and then is it doing its job. A pressure vacuum breaker vents a little from the top when the system shuts off and air enters. What is not normal is a steady stream or a continuous drip, which usually means a check valve is held open by debris, a spring has weakened or a seat is worn, and the assembly needs a rebuild. Water from a crack in the body, bonnet or a fitting, especially after a freeze, means the assembly is split and needs replacing. Either way, it is failing a test right now, so have it looked at.